CU/XLPE/PVC Unarmored N2XY YJV XLPE insulated power cables

N2XY XLPE Insulated Cable

These cables are used for electricity supply in low voltage installation system, They are suitable for: 

· installation in indoors and outdoors 

· in cable ducts

· under ground

· in power and switching stations

· local energy distributions

· industrial plants

where there is no risk of mechanical damage.


 For any more information or advice please contact the office on 0086-13229065196(WhatsApp/WeChat)


Share:

Details

XLPE Insulated,PVC Sheathed Cable,0.6/1kV

The 0.6/1 KV CU/XPLE/PVC cable plays a vital role in low-voltage power transmission and distribution, widely applied in building,industrial, and infrastructure settings to ensure the reliability and safety of power systems. This Power Cable with stranded compacted copper conductor(CU), cross-linked polyethylene insulation (XPLE), and a polyvinyl chloride sheath (PVC). For fixed installation in interiors,outdoor installation,in soil,in water and concrete,if no posterior mechanical damage is to be expected.

Construction



CU/XLPE/PVC Unarmored N2XY YJV XLPE insulated power cables

Description: N2XY, XLPE Insulated Copper Power Cable  

Conductors:Class 1 or Class 2 of plain copper,or of Class 5 of plain copper in accordance with IEC 60228.

Insulation:Cross-linked polyethylene XLPE

Insulation Colour:Natural or as required

Filler: Non-hygroscopic Material

Outer Sheath:Extruded Polyvinyl Chloride PVC&Polyethylene PE&LSZH

Colour of Sheath: Black

Voltage Rating (Uo/U):600/1000V   Test Voltage: 3.5kV for 5 minutes

Physical Properties

Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90(XLPE insulation)

Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)

Short Circuit Temperature(5 seconds maximum duration): 140-160℃(PVC insulation);250℃(XLPE insulation)

Technical Data

0.6/1kV-3+1 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
3X2.5+1X1.50.7/0.71.8 12.3 2007.41/12.12839
3X4+1X2.50.7/0.71.8 13.4 2604.61/7.413751
3X6+1X40.7/0.71.8 14.6 3503.08/4.614764
3X10+1X60.7/0.71.8 16.9 4801.83/3.086586
3X16+1X100.7/0.71.8 19.4 7601.15/1.8384110
3X25+1X160.9/0.71.8 22.8 10400.727/1.15110140
3X35+1X160.9/0.71.8 25.1 14200.524/1.15135170
3X50+1X251.0/0.91.8 28.2 18300.387/0.727170205
3X70+1X351.1/0.91.9 31.9 25000.268/0.524215250
3X95+1X501.1/1.02.135.7 34000.193/0.387265300
3X120+1X701.2/1.12.239.6 43000.153/0.268310345
3X150+1X701.4/1.12.343.6 52000.124/0.268350385
3X185+1X951.6/1.12.549.8 65000.0991/0.193405435
3X240+1X1201.7/1.22.755.3 85000.0754/0.153480500
3X300+1X1501.8/1.42.957.0 100000.0601/0.124555565
3X400+1X1852.0/1.73.170.0 133000.0470/0.0991640640
0.6/1kV-4+1 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
4X2.5+1X1.50.7/0.71.8 13.2 2207.41/12.12839
4X4+1X2.50.7/0.71.8 14.5 3204.61/7.413751
4X6+1X40.7/0.71.8 15.9 4203.08/4.614764
4X10+1X60.7/0.71.8 18.5 6501.83/3.086586
4X16+1X100.7/0.71.8 21.3 9501.15/1.8384110
4X25+1X160.9/0.71.8 25.7 14500.727/1.15110140
4X35+1X160.9/0.71.8 28.2 18500.524/1.15135170
4X50+1X251.0/0.91.9 28.9 25000.387/0.727170205
7X70+1X351.1/0.92.0 32.2 34500.268/0.524215250
4X95+1X501.1/1.02.236.9 47000.193/0.387265300
4X120+1X701.2/1.12.340.8 60000.153/0.268310345
4X150+1X701.4/1.12.544.7 71000.124/0.268350385
4X185+1X951.6/1.12.750.7 90000.0991/0.193405435
4X240+1X1201.7/1.22.956.4 104000.0754/0.153480500
4X300+1X1501.8/1.43.164.0 135000.0601/0.124555565
0.6/1kV-3+2 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
3X2.5+2X1.50.7/0.71.8 13.0 2007.41/12.12839
3X4+2X2.50.7/0.71.8 14.3 2604.61/7.413751
3X6+2X40.7/0.71.8 15.6 3503.08/4.614764
3X10+2X60.7/0.71.8 17.9 4801.83/3.086586
3X16+2X100.7/0.71.8 20.8 7601.15/1.8384110
3X25+2X160.9/0.71.8 25.2 10400.727/1.15110140
3X35+2X160.9/0.71.8 26.8 14200.524/1.15135170
3X50+2X251.0/0.91.9 28.7 18300.387/0.727170205
3X70+2X351.1/0.92.0 32.2 25000.268/0.524215250
3X95+2X501.1/1.02.236.7 34000.193/0.387265300
3X120+2X701.2/1.12.340.8 43000.153/0.268310345
3X150+2X701.4/1.12.444.5 52000.124/0.268350385
3X185+2X951.6/1.12.650.5 65000.0991/0.193405435
3X240+2X1201.7/1.22.856.1 85000.0754/0.153480500
3X300+2X1501.8/1.43.063.7 100000.0601/0.124555565






Contact Us Now